- Six-gas detection for the X30 One payload covers carbon monoxide, hydrogen sulphide, oxygen, combustible gas, carbon dioxide and nitrogen oxides.
- 0.01 ppm resolution on H2S and NOx Both channels resolve to 0.01 ppm across a 0–100 ppm range, with carbon monoxide resolved to 0.1 ppm up to 1,000 ppm.
- Combustible gas across the full LEL range An industrial-grade catalytic combustion element reads 0 to 100 %LEL at 0.1 %LEL resolution.
- Temperature and humidity in the same housing Readings run from −40 °C to +70 °C at 0.1 °C and from 0 to 100 %RH at 1 %RH, which is the context a gas figure has to be read against.
- Powered and controlled by the robot The X30 supplies power and control, so the payload adds no separate battery or operating station.
- Reporting through the X30's own interface Imagery and control pass through the robot's controller and software, keeping the operator at a distance from the atmosphere being measured.
Description
The MS600-W-7 is the gas detection payload specified for the Deep Robotics X30. Mount it on the robot and the X30 becomes an atmosphere-reading platform for substations, tunnels, plant rooms, confined spaces and incident sites — the places where the first thing anyone needs to know is what is in the air.
Six gases are covered: carbon monoxide to 0.1 ppm, hydrogen sulphide and nitrogen oxides to 0.01 ppm, oxygen to 0.01 %vol, carbon dioxide to 1 ppm and combustible gas across the full 0–100 %LEL range. A temperature channel spanning −40 °C to +70 °C and a humidity channel across 0–100 %RH are built into the same unit, which matters because both affect how a gas reading should be interpreted.
The X30 supplies the payload with power and control, and the operator sees imagery and issues control through the robot's own controller and software. Nothing separate has to be carried, read or logged by hand at the scene.
The MS600-W-6 is the same sensor suite specified for the M20. Ranges, resolutions and sensor types are identical between the two, and the suffix records which robot each is built for rather than any difference in measurement — so the choice follows your fleet. Enclosure dimensions, weight, power draw, ingress rating and calibration arrangements are confirmed with the order.
Key Capabilities
- Six-gas detection for the X30: One payload covers carbon monoxide, hydrogen sulphide, oxygen, combustible gas, carbon dioxide and nitrogen oxides.
- 0.01 ppm resolution on H2S and NOx: Both channels resolve to 0.01 ppm across a 0–100 ppm range, with carbon monoxide resolved to 0.1 ppm up to 1,000 ppm.
- Combustible gas across the full LEL range: An industrial-grade catalytic combustion element reads 0 to 100 %LEL at 0.1 %LEL resolution.
- Temperature and humidity in the same housing: Readings run from −40 °C to +70 °C at 0.1 °C and from 0 to 100 %RH at 1 %RH, which is the context a gas figure has to be read against.
- Powered and controlled by the robot: The X30 supplies power and control, so the payload adds no separate battery or operating station.
- Reporting through the X30's own interface: Imagery and control pass through the robot's controller and software, keeping the operator at a distance from the atmosphere being measured.
Buying through Robotix Market
This unit is sourced new through established distribution channels and ships worldwide with the manufacturer warranty. Technical support is coordinated with the manufacturer's own service network. Deployment scope, configuration, and commissioning responsibilities are agreed as part of the quotation — on-site installation is not included in the product price.
Features
Specs
| Brand | Eranntex |
|---|---|
| Model | MS600-W-7 |
| Product Type | Six-in-one gas detection payload with temperature and humidity |
| Compatible Platform | Deep Robotics X30 |
| Temperature Measurement | −40 °C to +70 °C, resolution 0.1 °C |
| Humidity Measurement | 0–100 %RH, resolution 1 %RH |
| Carbon Monoxide (CO) | 0–1,000 ppm, resolution 0.1 ppm, electrochemical sensor |
| Hydrogen Sulphide (H2S) | 0–100 ppm, resolution 0.01 ppm, electrochemical sensor |
| Oxygen (O2) | 0–30 %vol, resolution 0.01 %vol, electrochemical sensor |
| Combustible Gas (EX) | 0–100 %LEL, resolution 0.1 %LEL, industrial-grade catalytic combustion sensor |
| Carbon Dioxide (CO2) | 0–5,000 ppm, resolution 1 ppm, infrared sensor |
| Nitrogen Oxides (NOx) | 0–100 ppm, resolution 0.01 ppm, electrochemical sensor |
| Robot Interface | Power and control supplied by the robot |
| Controller Interface | Image and control |
| Software Interface | Image and control |
| Dimensions | Confirm at quote |
| Weight | Confirm at quote |
| Power Draw | Confirm at quote |
| Ingress Protection | Confirm at quote |
| Calibration Interval | Confirm at quote |
Industries
Frequently Asked Questions
It turns the robot into an atmosphere-reading platform, measuring six gases plus temperature and humidity and reporting through the robot's own controller and software.
Carbon monoxide 0–1,000 ppm, hydrogen sulphide 0–100 ppm, oxygen 0–30 %vol, combustible gas 0–100 %LEL, carbon dioxide 0–5,000 ppm and nitrogen oxides 0–100 ppm.
No. The X30 supplies power and control, and the operator works through the robot's existing controller and software.
The sensor suite and every measuring range match. The W-7 is specified for the X30 and the W-6 for the M20, and the suffix records that fit rather than a measurement difference.
The calibration interval and certification arrangements are confirmed in writing before you order.
The Eranntex MS600-W-7 Gas Sensor for Deep Robotics X30 is priced at 20 500 zł in your market.
Eranntex MS600-W-7 Gas Sensor for Deep Robotics X30
- Regular price
- 20 500,00 zł
- Sale price
Recently Viewed
You haven't viewed any products yet.